QLS-8100 Xe F-5
85 Field data string error
An invalid data string is part of the label format. Valid ASCII
characters are from 20h to FFh, and all data fields must be
terminated with an End Field Data command (<STX>FE). This error
results from any of the following:
Too much data (barcode, font, Data Matrix)
Data Matrix symbol that extends off the label
Bar-code field strings contain characters not supported by the
chosen symbology.
86 Print disable command error
Print disable command contains invalid parameters (<STX PD).
87 Field color error
An invalid color number has been specified. Valid field colors range
from 1 to 15.
88 PDF417 security level error
An invalid error correction (security) level has been specified for a
PDF417 bar code.
89 PDF417 reserved 1 error
Must be 0
90 PDF417 reserved 2 error
Must be 0
91 PDF417 reserved 3 error
Must be 0
92 UCC/EAN-128 composite error
Invalid height of CC