Notes:
●
If at any stage the scanning has not been completed properly, click
Reset and scan again.
●
If an error occurs while you are scanning the chart, an alert message
appears. Click OK and re-scan the charts.
6. To save the calibration table, do one of the following:
●
Select As default name to automatically name the
calibration table using the screening method, meda type,
and date.
●
Select Save as to type your own name.
Note: It is strongly recommended that you include the media type, weight,
and screening method in the calibration table file name.
7. Click Finish.
Mapping jobs to calibration tables
When you create a calibration table, the calibration table is based
on the media type, paper weight, and screening method that you
selected during the calibration process. Any job that has the
specific media type, paper weight, and screening method that you
selected, will automatically be mapped or linked to this calibration
table.
In the Job Parameters window, under Color > Calibration, the
Linked option is selected by default.
When you send your job to print, because the calibration table is
linked to the job, it is automatically used when the job is printed.
See also:
Mapping media using the Media and Color Manager
tool on page 52
Mapping jobs to calibration tables 21